▼
Scroll to page 2
of
38
GFXtermo4-GFX4 PROFINET MANUEL UTILISATEUR code: 80419B - 06-2014 - FRANCAIS SOMMAIRE Introduction..............................................................................................................................................2 Principales Caractéristiques............................................................................................................2 Raccordement des dispositifs...........................................................................................................4 CONNEXIONS ADMISSIBLES.....................................................................................................................4 Schéma de connexion 1 ( 4 zones ) ......................................................................................................4 Schéma de connexion 2 ( 8 zones ) ......................................................................................................4 Schéma de connexion 3 ( 12 zones ) ....................................................................................................5 Schéma de connexion 4 ( 16 zones ) ....................................................................................................6 Description de l’échange de données.........................................................................................7 Du fichier descriptif GSDML à l’échange de données............................................................ 7 Configuration pour le Schéma de Connexion 1 ( 4 zones ) ................................................ 11 Configuration pour le Schéma de Connexion 2 ( 8 zones ) ............................................... 14 Configuration pour le Schéma de Connexion 3 ( 12 zones ) .............................................. 14 Configuration pour le Schéma de Connexion 4 ( 16 zones ) .............................................. 15 SLOT virtuel 5 modbus ......................................................................................................................16 Diagnostic.................................................................................................................................................20 Mauvais réglage du commutateur 7............................................................................................20 Erreur de communication sur le port série modbus.......................................................... 21 BIBLIOTHEQUE SW “Gefran S7” POUr GFX4-GFXtermo4.............................................................. 22 INSTALLATION...........................................................................................................................................22 FONCTIONS...............................................................................................................................................26 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 1 Introduction La carte RTE (Real Time Ethernet) est un dispositif qui permet aux esclaves connectés de transmettre et recevoir des informations à partir du protocole Profinet. Le schéma conceptuel de raccordement est illustré dans la figure suivante. il y a : • Un maître Profinet-controller branché sur un dispositif Profinet-Io (Gefran RTE Profinet Bridge) via le protocole Profinet (en vert) • Un maître Modbus RTU en exécution sur la carte RTE ( Gefran Profinet Bridge), branché en série sur un Modbus esclave RTU • • • • • • • • • • • • • • • • • Principales Caractéristiques Module Profinet-Io ↔ Modbus RTU Deux ports Ethernet RJ45 : Eth 0 et Eth 1 Module switch interne Débit en bauds 100Mbits Auto_Negotiation, Auto_Polarity, Auto_Crossover Installation interne Data transport layer Ethernet II , IEEE 802.3 Support RTC – Real time Cyclic Protocol- Class 1 et Class 2 (non synchronisé) Support RTA – Real time Acyclic Protocol Adressage du dispositif via le protocole DCP – Discovery and Configuration Protocol (non DHCP) Support CL-RPC – Connectionless Remote Procedure Call Support LLDP – Link Layer Discovery Protocol Pas de démarrage rapide 32 mots d’entrée (16 bits par mot) pour chaque GFXtermo4-GFX4 32 mots de sortie (16 bits par mot) pour chaque GFXtermo4-GFX4 Intervalle minimum du dispositif pour les données cycliques Profinet cyclic 8ms Supporte le mode d’adressage GFX4 standard (commutateur 7 sur Off) commutateurs pour la configuration des fonctions • Temps minimum de communication série 50 ms pour 16 mots contigus, en utilisant la fonctionnalité custom map du GFXtermo4-GFX4 2 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA • Disponibilité de la diode signal DCP sur la façade de l’instrument 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 3 Raccordement des dispositifs L’échange interne de données du dispositif GFXtermo4-GFX4 s’effectue au travers de l’encapsulage des données modbus à l’intérieur des paquets Profinet. Le port série des dispositifs raccordés doit être configuré : • • • • • Vitesse de connexion sur port série 19200 bauds Pas de parité 8 bits de données Les adresses Modbus des noeuds DOIVENT être comprises entre 1 et 4 en séquence. L’instrument GFXtermo4-GFX4 doté de carte Profinet DOIT avoir l’adresse 1 CONNEXIONS ADMISSIBLES Les possibles combinaisons de connexion et d’adressage des modules GFXtermo4-GFX4 sont illustrées dans les pages suivantes. Toute combinaison de connexion qui ne figure pas parmi celles illustrées NE permet PAS la communication Profinet avec un dispositif Controller Schéma de connexion 1 (4 zones) : 1 GFX4 (ou GFXtermo4) avec adresse de nœud modbus = 1 et commutateur 7 sur Off. Schéma de connexion 2 ( 8 zones ): 2 GFX4 (ou GFXtermo4) avec adresses de nœud modbus = 1 et 2, commutateur 7 sur Off. 4 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Schéma de connexion 3 ( 12 zones ) : 3 GFX4 (ou GFXtermo4) avec adresses de nœud modbus = 1,2 et 3 et commutateur 7 sur Off. 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 5 Schéma de connexion 4 ( 16 zones ) : 4 GFX4 (ou GFXtermo4) avec adresse de nœud modbus = 1,2,3 et 4, commutateur 7 sur Off. 6 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Description de l’échange de données Le module Profinet-Io du dispositif GFXtermo4-GFX4 supporte les typologies de données suivantes • • • Données de paramétrage (Parameter data) Données cycliques (Cyclic data) Données asynchrones (Acyclic data) La caractérisation de ces données s’effectue via le fichier descriptif du dispositif (fichier GSDML ). L’interprétation du flux de données doit être connue par l’application qui produit/exploite les informations transmises/reçues par le dispositif. La carte Gefran Profinet-Io fait office de passerelle entre l’univers série modbus et l’univers ethernet Profinet. Les données suivent ce parcours : • • depuis le maître Profinet-controller vers l’esclave Profinet-Io et inversement, à travers les messageries acycliques (données asynchrones et paramétrages) ou bien à travers les données cycliques pour les données de processus rapide. A l’aide d’un outil de configuration, il est possible de définir les données du dispositif esclave qui seront échangées à travers les données cycliques rapides. Du fichier descriptif GSDML à l’échange de données Pour pouvoir activer l’échange de données, il faut disposer du fichier GSDML descriptif du produit ((GSDMLV2.3-GEFRAN-GFX4-GFXTERMO4-20121119.xml), à télécharger depuis le site www.gefran.com) et l’installer dans l’environnement de programmation. Après cette opération, l’on constatera la présence des dossiers Controllers→Geflex avec le module GFXtermo4GFX4 Standard Mode (Fig.1) Fig 1 Il est alors possible de réaliser la connexion au réseau (2), en déplaçant le dispositif (1), comme illustré dans la figure 2 Fig 2 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 7 Au cas où il serait nécessaire de programmer un nom/adresse IP du dispositif, il sera possible d’utiliser les menus PLC-->Ethernet-->Edit Ethernet Node depuis l’outil de configuration System Manager (Fig.3) Fig 3 A l’intérieur de la fenêtre Edit Ethernet Node, sélectionner le bouton Browse (Fig. 4) pour rechercher les nœuds connectés au réseau. Attendre quelques secondes Fig 4 8 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Au bout de quelques secondes, le système affichera la fenêtre Browse Network, laquelle récapitule les paramètres courants des nœuds connectés au réseau. Dans l’exemple, le réseau se compose de deux nœuds : • un contrôleur • un dispositif gfx4 ou GFXtermo4 Pour modifier les paramètres (Fig. 5) du gfx4 ou GFXtermo4, sélectionner la ligne Device type GEFLEX (1) et valider en appuyant sur la touche OK (2) Fig 5 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 9 Dans la fenêtre suivante (Fig. 6), il est possible de programmer le nom/adresse IP du dispositif. Le protocole DHCP n’est pas supporté Fig 6 10 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Voici comment ajouter un dispositif dans l’outil de configuration, dans la fenêtre Hw-config Configuration pour le Schéma de Connexion 1 ( 4 zones ) : Fig 7 Dans la figure 7, le dispositif GFXtermo4-GFX4 se trouve dans l’emplacement 1, qui gère 4 zones. Il existe aussi un canal modbus général dans la fente 5 (voir description du canal modbus). Si l’on sélectionne l’emplacement 1, comme illustré dans la figure 8: Fig 8 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 11 Il est possible de vérifier/modifier le paramétrage des variables Input/Output de processus. Fig 9 32 variables d’entrée sont disponibles en deux blocs • Input Parameter Record 1 ( 16 mots ) • Input Parameter Record 2 ( 16 mots ) Dans la colonne Value, il est possible de modifier la valeur du paramètre (Fig. 10) Fig 10 12 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 32 variables de sortie sont disponibles en deux blocs : • • Output Parameter Record 1 Output Parameter Record 2 Dans ce cas aussi, il est possible d’intervenir dans la colonne Value pour modifier les variables de sortie (Fig.11) Fig 11 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 13 Configuration pour le Schéma de Connexion 2 (8 zones ) : Depuis l’outil de configuration, sélectionner le module GFXtermo4-GFX4 Standard Mode et le déplacer dans l’emplacement 2. Le module modbus se trouve dans l’emplacement 5 (Fig.12) Fig 12 Dans la fenêtre des propriétés de chaque module, il est possible de paramétrer les données d’entrée/sortie, comme illustré plus haut. Configuration pour le Schéma de Connexion 3 (12 zones ) : Depuis l’outil de configuration, sélectionner le module GFXtermo4-GFX4 Standard Mode et le déplacer dans l’emplacement 2, puis dans l’emplacement 3. La module modbus se trouve dans l’emplacement 5 (Fig.13). Fig 13 Dans la fenêtre des propriétés de chaque module, il est possible de paramétrer les données d’entrée/sortie, comme illustré plus haut. 14 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Configuration pour le Schéma de Connexion 4 ( 16 zones ) : Depuis l’outil de configuration, sélectionner le module GFXtermo4-GFX4 Standard Mode et le déplacer dans l’emplacement 2 , 3 puis dans l’emplacement 4. La module modbus se trouve dans l’emplacement 5 (Fig.14). Fig 14 Dans la fenêtre des propriétés de chaque module, il est possible de paramétrer les données d’entrée/sortie, comme illustré plus haut. 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 15 L’emplacement virtuelle 5 modbus L’emplacement 5 (Fig.15) est un dispositif virtuel qui permet d’encapsuler une commande modbus parmi les données Profinet cycliques. Fig 15 Dans les paramètres du module, il est possible de configurer certains aspects liés à la communication. • Fault Mode (Fig.16) : en cas de coupure de la communication Profinet, des actions peuvent être entreprises pour configurer les modules comme suit √ √ √ √ N’entreprendre aucune action Commander le dispositif en mode Software Off Commander le dispositif en mode manuel Configurer SP2 en tant que Setpoint Fig 16 • Modbus Read Mode (Fig.17) : √ √ Normal Modbus read: tous les 32 mots d’entrée sont ajoutés en lecture (Input parameter record 1 et Input parameter record 2) Half Modbus read: si les variables en lecture nécessaires pour l’application sont égales au maximum à 16 mots, seuls les Input parameter record 1 sont actualisés. Fig 17 16 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA L’emplacement 5 modbus a des dimensions égales à 8 octets en écriture et 8 octets en lecture. Par le biais de ce canal, il est possible de lire ou d’écrire n’importe quelle variable parmi celles publiées dans la cartographie modbus des modules GFXtermo4-GFX4 connectés au réseau. Canal modbus, emplacement 5 de sortie, 8 octets Octet 1 Octet 2 Mot déclencheur d’interrogation Canal de sortie Modbus Octet 3 Adresse Modbus Octet 4 Octet 5 Octet 6 Octet 7 Octet 8 Code Fonction Données 1 Données 2 Données 3 Données 4 Canal modbus, emplacement 5 d’entrée, 8 octets Octet 1 Octet 2 Mot déclencheur de réponse OFFSET D’OCTETS Modbus INput channel Octet 3 Adresse Modbus Octet 4 Octet 5 Octet 6 Octet 7 Octet 8 Code Fonction Données 1 Données 2 Données 3 Données 4 PARAMETRE 0 Mot déclencheur d’interrogation/ réponse 2 Adresse ESCLAVE 4 Données 1 3 5 6 7 Description Code Fonction Données 2 Données 3 Données 4 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Description Mot DECLENCHEUR d’interrogation : il doit être augmenté de 1 à chaque nouvelle interrogation. La réponse est valide lorsque le mot déclencheur de réponse est le même que le mot DECLENCHEUR d’interrogation. Adresse MODBUS du GFXtermo4-GFX4 Code Fonction Lecture/Ecriture Bit/Mot Dépend du CODE FONCTION Dépend du CODE FONCTION Dépend du CODE FONCTION Dépend du CODE FONCTION 17 Lecture bit (1,2) INTERROGATION TRG ADRESSE ESCLAVE CODE FONCTION ADRESSE BIT OCTET + SIGNIF. ADRESSE BIT OCTET SIGNIF. Mot déclencheur d’interrogation Adresse Esclave 1 ou 2 Adresse du bit à lire Adresse du bit à lire TRG ADRESSE ESCLAVE CODE FONCTION Nombre d’octets Mot déclencheur de réponse Adresse Esclave Code fonction de confirmation NOMBRE DE BITS OCTET + SIGNIF. NOMBRE DE BITS OCTET SIGNIF. BIT BIT # Valeur des bits (1÷8) Valeur des bits (9÷16) Fictif NUMERO WORD + SIGNIFICATIVO NUMERO WORD SIGNIFICATIVO MOT DE DONNEES - SIGNIF. # REPONSE Nombre d’octets (1 ou 2) Nombre de bits à lire. Doit être = 0 Nombre de bits à lire. Lecture d’un mot (3,4) TRG ADRESSE ESCLAVE CODE FONCTION Mot déclencheur d’interrogation Adresse Esclave 3 ou 4 TRG Mot déclencheur de réponse ADRESSE ESCLAVE Adresse Esclave CODE FONCTION Code fonction INTERROGATION ADRESSE BIT OCTET + SIGNIF. Adresse mot à lire ADRESSE BIT OCTET SIGNIF. Adresse mot à lire REPONSE NOMBRE D’OCTETS Nombre d’octets lus MOT DE DONNEES + SIGNIF. Valeur 0 1 Valeur Fictif BIT # Ecriture bit (5) TRG Mot déclencheur d’interrogation TRG Mot déclencheur de réponse 18 ADRESSE ESCLAVE Adresse esclave ADRESSE ESCLAVE CODE FONCTION 5 CODE FONCTION Adresse Code de esclave confirmation INTERROGATION ADRESSE + SIGNIF. Adresse bit à écrire ADRESSE SIGNIF. Adresse bit à Valeur du bit écrire 00 = off ou FFhex = on) REPONSE 0 ADRESSE + SIGNIF. ADRESSE SIGNIF. BIT 00 Adresse bit écrite Adresse bit écrite Valeur du bit 00 = off ou FFhex = on) 0 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Ecriture d’un mot (6) TRG Mot déclencheur d’interrogation TRG Mot déclencheur de réponse ADRESSE ESCLAVE ADRESSE ESCLAVE ADRESSE ESCLAVE CODE FONCTION 6 CODE FONCTION Adresse Code de esclave confirmation INTERROGATION ADRESSE + SIGNIF ADRESSE SIGNIF Adresse mot à écrire Adresse mot à écrire REPONSE ADRESSE + SIGNIF ADRESSE SIGNIF Adresse mot écrite Adresse mot écrite DONNEES + SIGNIF. DONNEES SIGNIF. Valeur mot à écrire Valeur mot à écrire DONNEES + SIGNIF. DONNEES SIGNIF. Valeur mot écrite Valeur mot écrite En cas d’erreur, la valeur Code Fonction d’interrogation, ajoutée à 80hex, est restituée dans le Code Fonction du message de réponse. TRG Mot déclencheur de réponse Code d’Erreur 1 illegal FC ADRESSE ESCLAVE Confirmer adresse Esclave CODE FONCTION Code fonction d’interrogation + 80hex 2 illegal data address REPONSE Code d’erreur Code d’erreur 3 illegal data 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA # # # fictif fictif fictif 9 illegal number of data 10 Data is read Only 19 Diagnostic Mauvais réglage du commutateur 7 Comme cela a déjà été rappelé, le dispositif GFXtermo4-GFX4 DOIT fonctionner en mode Geflex standard, avec le commutateur 7 sur OFF lors de la mise sous tension. Si le dispositif démarre avec le commutateur 7 sur ON, la communication ne peut avoir lieu. Un message d’erreur (Fig.18) est alors envoyé au poste Profinet-Controller. Fig 18 L’emplacement indiquée dans le message de diagnostic correspond au nœud du dispositif avec le commutateur 7 mal réglé. 20 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Défaut de communication sur le Modbus serie Cela apparaît lorsque la communication entre le Maître Modbus de la carte Profinet-IO et l’escalve Modbus dans la GFXtermo4-GFX4 échouse, comme illustré sur la figure 19 Figure 19 Quand cela apparaît, le module Profinet-IO envoie au Profinet-Controller le message d’erreur de communicaton Fig.20 Figure 20 Le slot spécifié sur message d’erreur correspond au noeud de l’appareil sur lequel le défaut apparaît. 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 21 BIBLIOTHÈQUES SW “Gefran S7” pour GFX4-GFXtermo4 INSTALLATION GEFRAN S.p.A. fournit une série de fichiers de la bibliothèque pour faciliter l’installation de la GFX4 et GFXtermo4 et de la gestion des données de processus dans l’environnement de SIEMENS STEP7. Ces bibliothèques sont contenues dans un fichier compressé “GefranProfinet_V2-00.zip” sur le CD inclus avec le produit ou téléchargeable sur www.gefran.com Après le lancement de SIMATIC Manager, cliquez sur désarchivez dans le menu déroulant fichier et ouvrez le fichier “GefranProfinet_V2-00.zip” dans le dossier dans lequel il a été copié. Puis selectionner le dossier de destinations dans ..STEP7/S7Proj. A la fin de l’extraction, en sélectionnant la commande “Ouvrir projet” dans le menu déroulant “Fichier” et on pourra accéder à la librairie “GefranProfinet_V2-00” du GFX4 et GFXtermo4. 22 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Elle contient des Blocs Fonctionnels, des Blocs de Données et des Fonctions: GFX4 en modalitè HIGH PERFORMANCE OBJECT UDT6 DESCRIPTION Data type for managing Process datA FC4 Management of Process Data area FC3 anagement function data PARAMETRIC UDT5 FB1 FB15 Block acyclic data exchange Function block to manage parameters Function block to manage parameter recipes 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 23 FONCTIONS UDT6 Type de données pour gestion données de processus des GFX4 Bloc des données en lecture depuis l’adresse word 0 jusqu’à l’adresse word 62 Bloc des données en écriture depuis l’adresse word 64 jusqu’à l’adresse word 126 Address Name 0.0 + 0.0 GFX4_Read_W01 + 2.0 GFX4_Read_W02 + 4.0 GFX4_Read_W03 + 6.0 GFX4_Read_W04 + 8.0 GFX4_Read_W05 + 10.0 GFX4_Read_W06 + 12.0 GFX4_Read_W07 + 14.0 GFX4_Read_W08 + 16.0 GFX4_Read_W09 + 18.0 GFX4_Read_W10 + 20.0 GFX4_Read_W11 + 22.0 GFX4_Read_W12 + 24.0 GFX4_Read_W13 + 26.0 GFX4_Read_W14 + 28.0 GFX4_Read_W15 + 30.0 GFX4_Read_W16 + 32.0 GFX4_Read_W17 + 34.0 GFX4_Read_W18 + 36.0 GFX4_Read_W19 + 38.0 GFX4_Read_W20 + 40.0 GFX4_Read_W21 + 42.0 GFX4_Read_W22 + 44.0 GFX4_Read_W23 + 46.0 GFX4_Read_W24 + 48.0 GFX4_Read_W25 + 50.0 GFX4_Read_W26 + 52.0 GFX4_Read_W27 + 54.0 GFX4_Read_W28 + 56.0 GFX4_Read_W29 + 58.0 GFX4_Read_W30 + 60.0 GFX4_Read_W31 + 62.0 GFX4_Read_W32 + 64.0 GFX4_Write_W01 + 66.0 GFX4_Write_W02 + 68.0 GFX4_Write_W03 + 70.0 GFX4_Write_W04 24 Type STRUCT Initial value Comment INT 0 GFX4 Read Process Word 01 INT 0 GFX4 Read Process Word 02 INT 0 GFX4 Read Process Word 03 INT 0 GFX4 Read Process Word 04 INT 0 GFX4 Read Process Word 05 INT 0 GFX4 Read Process Word 06 INT 0 GFX4 Read Process Word 07 INT 0 GFX4 Read Process Word 08 INT 0 GFX4 Read Process Word 09 INT 0 GFX4 Read Process Word 10 INT 0 GFX4 Read Process Word 11 INT 0 GFX4 Read Process Word 12 INT 0 GFX4 Read Process Word 13 INT 0 GFX4 Read Process Word 14 INT 0 GFX4 Read Process Word 15 INT 0 GFX4 Read Process Word 16 INT 0 GFX4 Read Process Word 17 INT 0 GFX4 Read Process Word 18 INT 0 GFX4 Read Process Word 19 INT 0 GFX4 Read Process Word 20 INT 0 GFX4 Read Process Word 21 INT 0 GFX4 Read Process Word 22 INT 0 GFX4 Read Process Word 23 INT 0 GFX4 Read Process Word 24 INT 0 GFX4 Read Process Word 25 INT 0 GFX4 Read Process Word 26 INT 0 GFX4 Read Process Word 27 INT 0 GFX4 Read Process Word 28 INT 0 GFX4 Read Process Word 29 INT 0 GFX4 Read Process Word 30 INT 0 GFX4 Read Process Word 31 INT 0 GFX4 Read Process Word 32 INT 0 GFX4 Write Process Word 01 INT 0 GFX4 Write Process Word 02 INT 0 GFX4 Write Process Word 03 INT 0 GFX4 Write Process Word 04 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Address Name + 72.0 GFX4_Write_W05 + 74.0 GFX4_Write_W06 + 76.0 GFX4_Write_W07 + 78.0 GFX4_Write_W08 + 80.0 GFX4_Write_W09 + 82.0 GFX4_Write_W10 + 84.0 GFX4_Read_W11 + 86.0 GFX4_Read_W12 + 88.0 GFX4_Read_W13 + 90.0 GFX4_Read_W14 + 92.0 GFX4_Read_W15 + 94.0 GFX4_Write_W16 + 96.0 GFX4_Write_W17 + 98.0 GFX4_Write_W18 + 100.0 GFX4_Write_W19 + 102.0 GFX4_Write_W20 + 104.0 GFX4_Write_W21 + 106.0 GFX4_Write_W22 + 108.0 GFX4_Write_W23 Type INT Initial value Comment 0 GFX4 Write Process Word 05 INT 0 GFX4 Write Process Word 06 INT 0 GFX4 Write Process Word 07 INT 0 GFX4 Write Process Word 08 INT 0 GFX4 Write Process Word 09 INT 0 GFX4 Write Process Word 10 INT 0 GFX4 Write Process Word 11 INT 0 GFX4 Write Process Word 12 INT 0 GFX4 Write Process Word 13 INT 0 GFX4 Write Process Word 14 INT 0 GFX4 Write Process Word 15 INT 0 GFX4 Write Process Word 16 INT 0 GFX4 Write Process Word 17 INT 0 GFX4 Write Process Word 18 INT 0 GFX4 Write Process Word 19 INT 0 GFX4 Write Process Word 20 INT 0 GFX4 Write Process Word 21 INT 0 GFX4 Write Process Word 22 INT 0 GFX4 Write Process Word 23 + 112.0 GFX4_Write_W25 INT 0 GFX4 Write Process Word 24 INT 0 GFX4 Write Process Word 25 + 116.0 GFX4_Write_W27 INT 0 GFX4 Write Process Word 26 INT 0 GFX4 Write Process Word 27 INT 0 GFX4 Write Process Word 28 INT 0 GFX4 Write Process Word 29 INT 0 GFX4 Write Process Word 30 INT 0 GFX4 Write Process Word 31 INT 0 GFX4 Write Process Word 32 + 110.0 GFX4_Write_W24 + 114.0 GFX4_Write_W26 + 118.0 GFX4_Write_W28 + 120.0 GFX4_Write_W29 + 122.0 GFX4_Write_W30 + 124.0 GFX4_Write_W31 + 126.0 GFX4_Write_W32 = 128.0 END_STRUCT 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 25 FONCTIONS FC4 “FC_PD_GFX4” (FUNCTION CALL) ” Fonction de gestion traite la zone GFX4 donné. Cette fonction met à disposition la zone d’échange de données de processus entre le PLC and GFX4 (ou GFXtermo4) dans le bloc données crée avec l’UDT6 décrit plus haut. FC4 doit être appelée à chaque scrutation pour assurer la mise à jour des données. Deux paramètres d’entrée sont requis: 1. FirstByte : 2. DBNr : (INT) La première adresse mémoire attribuée au rack GFX4 (ou GFXtermo4) dans la configuration matérielle. (INT) le numéro du bloc de données crée avec l’UDT6 pour l’échange de données entre la GFX4 (ou GFXtermo4) et le PLC First byte 26 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA La figure ci-dessous montre une connexion avec 4 esclaves 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 27 UDT5 Bloc d’échange acyclique des données Address Name 0.0 + 0.0 Trigger Type STRUCT Initial value Comment + 1.0 Cont BYTE B#16#0 Reserved BYTE B#16#0 Reserved + 4.0 ParamByte3 WORD W#16#0 Request Byte 1 e 2 + 5.0 ParamByte4 BYTE B#16#0 Request Byte 3 BYTE B#16#0 Request Byte 4 + 7.0 ParamByte6 BYTE B#16#0 Request Byte 5 + 8.0 ParamByte7 BYTE B#16#0 Request Byte 6 BYTE B#16#0 Request Byte 7 + 10.0 StatusWord1 BYTE B#16#0 Request Byte 8 + 12.0 StatusByte3 WORD W#16#0 Answer Byte 1 e 2 BYTE B#16#0 Answer Byte 3 + 14.0 StatusByte5 BYTE B#16#0 Answer Byte 4 + 15.0 StatusByte6 BYTE B#16#0 Answer Byte 5 BYTE B#16#0 Answer Byte 6 + 17.0 StatusByte8 BYTE B#16#0 Answer Byte 7 BYTE B#16#0 Answer Byte 8 + 2.0 ParamWord1 + 6.0 ParamByte5 + 9.0 ParamByte8 + 13.0 StatusByte4 + 16.0 StatusByte7 + 18.0 ParamWriteDiag + 20.0 StatusReadDiag = 22.0 INT 0 Status Word write param operation INT 0 Status Word read param operation END_STRUCT FC3 “FC_CFG_GFX4” (FUNCTION CALL) ” Fonction gestion de l’espace des données paramétrique du GFX4 Cette fonction s’occupe de rendre disponibles, dans le bloc de données créé avec les UDT5 décrits au paragraphe précédent, les Données Paramétriques de l’instrument, nécessaires pour le fonctionnement du FB1. Le FC doit être rappelé dans l’OB1, sans conditions, de manière à ce que les données soient réactualisées lors de chaque exploration Deux paramètres d’entrée seront demandés: 1. FirstByte : (INT) est la première adresse de mémoire attribuée au GFX4 (ou GFXtermo4) dans la configuration matérielle. 2. DBNr : (INT) est le numéro du bloc de données créé avec l’UDT5 pour l’échange de données entre le GFX4 (ou GFXtermo4) et le PLC. 28 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA First byte 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 29 BLOCS DE FONCTIONS Tous les Blocs de Fonctions requièrent un DB d’instance, qui peut être librement attribué. Ils ne sont rappelés qu’à la demande et maintenus actifs jusqu’au terme de l’opération. Généralement, l’on définit un bit qui habilite la branche (EN) et qui est remis à zéro avec le front de montée du bit “Opération terminée” (Done). FB1 “FB_OP_GFX4” (FUNCTION BLOCK) Il s’occupe de gérer les principales opérations des Données Paramétriques pour la configuration du GFX4. Quatre opérations sont disponibles : 1. Lecture bit (op. code 1) 2. Lecture mot (op. code 3) 3. Ecriture bit (op. code 5) 4. Ecriture mot (op. code 6) Ce bloc requiert 5 paramètres d’entrée et répond par 4 paramètres de sortie. Paramètres d’entrée : 1. DBNr (INT) : numéro du bloc de données associé au GFX4 à interroger ou commander. 2. SlaveNr (INT) : adresse MODBUS de l’esclave avec lequel on souhaite opérer. 3. OPCode (INT) : code opération permettant à la fonction de savoir si l’on veut lire ou écrire un mot ou un bit. Les codes opérations sont les suivants: • Lecture bit Code Opération : 1 • Lecture mot Code Opération : 3 • Ecriture bit Code Opération : 5 • Ecriture mot Code Opération : 6 4. Address (INT) : adresse du mot/bit à lire/écrire. (Se reporter au manuel GFX4 pour l’identification des adresses MODBUS des mots/bits). 5. INValue (INT) : valeur à écrire dans le mot ou le bit sélectionné. En cas d’écriture d’un bit, seules les valeurs 1 et 0 sont naturellement admises. Dans les opérations de lecture, ce paramètre est ignoré. 30 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Paramètres de sortie : - Done (BOOL): sa valeur est égale à 1 lorsque l’opération de lecture est terminée. - OUTValue (INT) : valeur lue dans le mot ou le bit spécifié. Dans les opérations d’écriture, elle est égale à 1 si l’action a bien abouti ou à 0 si elle s’est terminée par une erreur - Error (BOOL): sa valeur est égale à 1 lorsque l’opération s’est terminée par une erreur. - ErrCode (INT): code de l’erreur constatée : 1 Illegal function 2 Illegal data address 3 Illegal data value 6 Slave device busy 9 Illegal number data 10 Read only data 20 Timeout Communication 21 Input value error 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 31 FB15 “FB_RCP_GFX4” (FUNCTION BLOCK) Stockage dans un DB d’un jeu de paramètres en provenance d’un GFX4 ou bien envoi vers un GFX4 d’un jeu de paramètres contenus dans un DB. Paramètres d’entrée : - DB_GFX (INT) : indiquer le numéro (paramètre en chiffres ou variable INT qui en contienne la valeur) du DB associé au GFX4 sur lequel on souhaite opérer. - DBIST (BLOCK_DB) : indiquer le nom (utiliser le nom symbolique du DB ou l’indication “DBxx” en entier) du DB d’instance du FB1 “OP_GFX4”, destiné au GFX4. - GFXNr (INT) : l’adresse du GFX4 avec lequel on souhaite opérer. - RCP_DB (INT) : le numéro du DB dans ou depuis lequel écrire/lire le jeu de données. - Funct (BOOL) : le type d’opération à exécuter : False = Store (enregistrer les paramètres du GFX4 dans le DB) True = Load (télécharger dans le GFX4 les paramètres enregistrés dans le DB) - ParamNr (INT) : le nombre de paramètres à enregistrer/lire. - ParamListDB (INT) : numéro du DB dans lequel chaque ligne spécifie l’adresse Modbus des paramètres à lire/écrire. Paramètres de sortie : - Done (BOOL) : sa valeur est égale à 1 lorsque l’opération est terminée. - Error (BOOL) : sa valeur est égale à 1 lorsqu’une erreur est survenue pendant l’opération d’écriture. - ErrorCode (INT) : en cas d’erreur, son code s’affiche 1 Fonction illicite 2 Adresse données illicite 3 Valeur données illicite 6 Dispositif esclave occupé 9 Nombre de données illicite 10 Données en lecture seulement 20 Timeout communication 21 Erreur valeur d’entrée - ErrorParamNr (INT) : en cas d’erreur, le numéro ordinaire du DB apparaît, avec la liste des adresses du paramètre qui a provoqué l’erreur 32 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA UDT4 Liste des adresses Modbus des paramètres utilisés dans FB15 Address Name 0.0 + 0.0 tYP_Zone_1 + 2.0 HiS_Zone_1 + 4.0 HStA_Zone_1 + 6.0 Ctr_Zone_1 + 8.0 HpH_Zone_1 + 10.0 HpL_Zone_1 + 12.0 HiL_Zone_1 + 14.0 ALn_Zone_1 + 16.0 A1r_Zone_1 + 18.0 A2r_Zone_1 + 20.0 A1t_Zone_1 + 22.0 A2t_Zone_1 + 24.0 HbF_Zone_1 + 26.0 Hbt_Zone_1 + 28.0 Lbt_Zone_1 + 30.0 HPb_Zone_1 + 32.0 CPb_Zone_1 + 34.0 Hit_Zone_1 + 36.0 Cit_Zone_1 + 38.0 Hdt_Zone_1 + 40.0 Cdt_Zone_1 + 42.0 AL1_Zone_1 + 44.0 AL2_Zone_1 + 46.0 ALHb_Zone_1 + 48.0 tYP_Zone_2 + 50.0 HiS_Zone_2 + 52.0 HStA_Zone_2 + 54.0 Ctr_Zone_2 + 56.0 HpH_Zone_2 + 58.0 HpL_Zone_2 + 60.0 HiL_Zone_2 + 62.0 ALn_Zone_2 + 64.0 A1r_Zone_2 + 66.0 A2r_Zone_2 + 68.0 A1t_Zone_2 + 70.0 A2t_Zone_2 + 72.0 HbF_Zone_2 + 74.0 Hbt_Zone_2 + 76.0 Lbt_Zone_2 + 78.0 HPb_Zone_2 + 80.0 CPb_Zone_2 Type STRUCT Initial value Comment INT 1424 Probe/Input type (1424) Zone 1 INT 1426 Max Input (1426) Zone 1 INT 1429 Max limit TA (1429) Zone 1 INT 1204 Control Type (1204) Zone 1 INT 1066 Max power heating % (1066) Zone 1 INT 1278 Min power heating % (1278) Zone 1 INT 1050 Max Setpoint (1050) Zone 1 INT 1219 Alarms enabling (1219) Zone 1 INT 1239 Alarm 1 reference (1239) Zone 1 INT 1240 Alarm 2 reference (1240) Zone 1 INT 1430 Alarm 1 type (1430) Zone 1 INT 1431 Alarm 2 type (1431) Zone 1 INT 1081 Alarm HB type (1081) Zone 1 INT 1080 Delay time for alarm HB (1080) Zone 1 INT 1068 Delay time for alarm LBA (1068) Zone 1 INT 1029 Heating Proportional bande (1029) Zone 1 INT 1030 Cooling Proportional bande (1030) Zone 1 INT 1031 Heating Integral Time (1031) Zone 1 INT 1100 Cooling Integral Time (1100) Zone 1 INT 1032 Heating Derivative Time (1032) Zone 1 INT 1101 Cooling Derivative Time (1101) Zone 1 INT 1036 Alarm 1 Min Temp (1036) Zone 1 INT 1037 Alarm 2 Max Temp (1037) Zone 1 INT 1079 Alarm Hb Amper (1079) Zone 1 INT 2448 Probe/Input type (2448) Zone 2 INT 2450 Max Input (2450) Zone 2 INT 2453 Max limit TA (2453) Zone 2 INT 2228 Control Type (2228) Zone 2 INT 2090 Max power heating % (2090) Zone 2 INT 2302 Min power heating % (2302) Zone 2 INT 2074 Max Setpoint (2074) Zone 2 INT 2243 Alarms enabling (2243) Zone 2 INT 2263 Alarm 1 reference (2263) Zone 2 INT 2264 Alarm 2 reference (2264) Zone 2 INT 2454 Alarm 1 type (2454) Zone 2 INT 2455 Alarm 2 type (2455) Zone 2 INT 2105 Alarm HB type (2105) Zone 2 INT 2104 Delay time for alarm HB (2104) Zone 2 INT 2092 Delay time for alarm LBA (2092) Zone 2 INT 2053 Heating Proportional bande (2053) Zone 2 INT 2054 Cooling Proportional bande (2054) Zone 2 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 33 Address Name Initial value Comment + 82.0 Hit_Zone_2 INT + 86.0 Hdt_Zone_2 INT 2124 Cooling Integral Time (2124) Zone 2 + 88.0 Cdt_Zone_2 INT 2056 Heating Derivative Time (2056) Zone 2 INT 2125 Cooling Derivative Time (2125) Zone 2 + 92.0 AL2_Zone_2 INT 2060 Alarm 1 Min Temp (2060) Zone 2 + 94.0 ALHb_Zone_2 INT 2061 Alarm 2 Max Temp (2061) Zone 2 INT 2103 Alarm Hb Amper (2103) Zone 2 + 98.0 HiS_Zone_3 INT 4496 Probe/Input type (4496) Zone 3 INT 4498 Max Input (4498) Zone 3 + 102.0 Ctr_Zone_3 INT 4501 Max limit TA (4501) Zone 3 INT 4276 Control Type (4276) Zone 3 + 106.0 HpL_Zone_3 INT 4138 Max power heating % (4138) Zone 3 + 108.0 HiL_Zone_3 INT 4350 Min power heating % (4350) Zone 3 INT 4122 Max Setpoint (4122) Zone 3 + 112.0 A1r_Zone_3 INT 4291 Alarms enabling (4291) Zone 3 + 114.0 A2r_Zone_3 INT 4311 Alarm 1 reference (4311) Zone 3 INT 4312 Alarm 2 reference (4312) Zone 3 + 118.0 A2t_Zone_3 INT 4502 Alarm 1 type (4502) Zone 3 + 120.0 HbF_Zone_3 INT 4503 Alarm 2 type (4503) Zone 3 INT 4153 Alarm HB type (4153) Zone 3 + 124.0 Lbt_Zone_3 INT 4152 Delay time for alarm HB (4152) Zone 3 + 126.0 HPb_Zone_3 INT 4140 Delay time for alarm LBA (4140) Zone 3 INT 4101 Heating Proportional bande (4101) Zone 3 + 130.0 Hit_Zone_3 INT 4102 Cooling Proportional bande (4102) Zone 3 INT 4103 Heating Integral Time (4103) Zone 3 + 134.0 Hdt_Zone_3 INT 4172 Cooling Integral Time (4172) Zone 3 INT 4104 Heating Derivative Time (4104) Zone 3 + 138.0 AL1_Zone_3 INT 4173 Cooling Derivative Time (4173) Zone 3 + 140.0 AL2_Zone_3 INT 4108 Alarm 1 Min Temp (4108) Zone 3 INT 4109 Alarm 2 Max Temp (4109) Zone 3 + 144.0 tYP_Zone_4 INT 4151 Alarm Hb Amper (4151) Zone 3 + 146.0 HiS_Zone_4 INT 8592 Probe/Input type (8592) Zone 4 INT 8594 Max Input (8594) Zone 4 + 150.0 Ctr_Zone_4 INT 8597 Max limit TA (8597) Zone 4 + 152.0 HpH_Zone_4 INT 8372 Control Type (8372) Zone 4 INT 8234 Max power heating % (8234) Zone 4 + 156.0 HiL_Zone_4 INT 8446 Min power heating % (8446) Zone 4 + 158.0 ALn_Zone_4 INT 8218 Max Setpoint (8218) Zone 4 INT 8387 Alarms enabling (8387) Zone 4 + 162.0 A2r_Zone_4 INT 8407 Alarm 1 reference (8407) Zone 4 INT 8408 Alarm 2 reference (8408) Zone 4 + 166.0 A2t_Zone_4 INT 8598 Alarm 1 type (8598) Zone 4 INT 8599 Alarm 2 type (8599) Zone 4 + 170.0 Hbt_Zone_4 INT 8249 Alarm HB type (8249) Zone 4 INT 8248 Delay time for alarm HB (8248) Zone 4 + 84.0 Cit_Zone_2 + 90.0 AL1_Zone_2 + 96.0 tYP_Zone_3 + 100.0 HStA_Zone_3 + 104.0 HpH_Zone_3 + 110.0 ALn_Zone_3 + 116.0 A1t_Zone_3 + 122.0 Hbt_Zone_3 + 128.0 CPb_Zone_3 + 132.0 Cit_Zone_3 + 136.0 Cdt_Zone_3 + 142.0 ALHb_Zone_3 + 148.0 HStA_Zone_4 + 154.0 HpL_Zone_4 + 160.0 A1r_Zone_4 + 164.0 A1t_Zone_4 + 168.0 HbF_Zone_4 34 Type 2055 Heating Integral Time (2055) Zone 2 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Address Name + 172.0 Lbt_Zone_4 Type INT Initial value Comment 8236 Delay time for alarm LBA (8236) Zone 4 8197 Heating Proportional bande (8197) Zone 4 + 174.0 HPb_Zone_4 INT + 178.0 Hit_Zone_4 INT 8198 Cooling Proportional bande (8198) Zone 4 INT 8199 Heating Integral Time (8199) Zone 4 INT 8268 Cooling Integral Time (8268) Zone 4 + 176.0 CPb_Zone_4 + 180.0 Cit_Zone_4 + 182.0 Hdt_Zone_4 INT 8200 Heating Derivative Time (8200) Zone 4 + 186.0 AL1_Zone_4 INT 8269 Cooling Derivative Time (8269) Zone 4 INT 8204 Alarm 1 Min Temp (8204) Zone 4 + 190.0 ALHb_Zone_4 INT 8205 Alarm 2 Max Temp (8205) Zone 4 INT 8247 Alarm Hb Amper (8247) Zone 4 + 184.0 Cdt_Zone_4 + 188.0 AL2_Zone_4 = 192.0 END_STRUCT 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA 35 DB20 Liste des paramètres utilisés dans FB15 Address Name 0.0 + 0.0 tYP_Zone_1 + 2.0 HiS_Zone_1 + 4.0 HStA_Zone_1 + 6.0 Ctr_Zone_1 + 8.0 HpH_Zone_1 + 10.0 HpL_Zone_1 + 12.0 HiL_Zone_1 STRUCT Initial value Comment INT 2 INT 1000 Probe/Input type Zone 1 Max Input Zone 1 INT 1400 Max limit TA Zone 1 INT 14 INT 1000 Control Type Zone 1 Max power heating % Zone 1 INT 0 Min power heating % Zone 1 INT 300 Max Setpoint Zone 1 INT 19 Alarms enabling Zone 1 + 18.0 A2r_Zone_1 INT 0 Alarm 1 reference Zone 1 INT 0 Alarm 2 reference Zone 1 + 22.0 A2t_Zone_1 INT 3 Alarm 1 type Zone 1 + 24.0 HbF_Zone_1 INT 2 Alarm 2 type Zone 1 INT 0 Alarm HB type Zone 1 + 28.0 Lbt_Zone_1 INT 30 Delay time for alarm HB Zone 1 INT 300 Delay time for alarm LBA Zone 1 INT 12 Heating Proportional bande Zone 1 INT 10 Cooling Proportional bande Zone 1 + 36.0 Cit_Zone_1 INT 527 Heating Integral Time Zone 1 INT 100 Cooling Integral Time Zone 1 + 40.0 Cdt_Zone_1 INT 131 Heating Derivative Time Zone 1 INT 100 Cooling Derivative Time Zone 1 INT -10 Alarm 1 Min Temp Zone 1 INT 20 Alarm 2 Max Temp Zone 1 INT 360 Alarm Hb Amper Zone 1 INT 2 INT 1000 Max Input Zone 2 INT 1400 Max limit TA Zone 2 INT 14 INT 1000 + 14.0 ALn_Zone_1 + 16.0 A1r_Zone_1 + 20.0 A1t_Zone_1 + 26.0 Hbt_Zone_1 + 30.0 HPb_Zone_1 + 32.0 CPb_Zone_1 + 34.0 Hit_Zone_1 + 38.0 Hdt_Zone_1 + 42.0 AL1_Zone_1 + 44.0 AL2_Zone_1 + 46.0 ALHb_Zone_1 + 48.0 tYP_Zone_2 + 50.0 HiS_Zone_2 + 52.0 HStA_Zone_2 + 54.0 Ctr_Zone_2 + 56.0 HpH_Zone_2 + 58.0 HpL_Zone_2 Probe/Input type Zone 2 Control Type Zone 2 Max power heating % Zone 2 INT 0 + 62.0 ALn_Zone_2 INT 300 Max Setpoint Zone 2 INT 19 Alarms enabling Zone 2 + 66.0 A2r_Zone_2 INT 0 Alarm 1 reference Zone 2 + 68.0 A1t_Zone_2 INT 0 Alarm 2 reference Zone 2 INT 3 Alarm 1 type Zone 2 + 72.0 HbF_Zone_2 INT 2 Alarm 2 type Zone 2 INT 0 Alarm HB type Zone 2 INT 30 Delay time for alarm HB Zone 2 INT 300 Delay time for alarm LBA Zone 2 INT 12 Heating Proportional bande Zone 2 INT 10 Cooling Proportional bande Zone 2 + 60.0 HiL_Zone_2 + 64.0 A1r_Zone_2 + 70.0 A2t_Zone_2 + 74.0 Hbt_Zone_2 + 76.0 Lbt_Zone_2 + 78.0 HPb_Zone_2 + 80.0 CPb_Zone_2 36 Type Min power heating % Zone 2 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Address Name + 82.0 Hit_Zone_2 Type INT Initial value Comment 527 Heating Integral Time Zone 2 100 Cooling Integral Time Zone 2 + 84.0 Cit_Zone_2 INT + 88.0 Cdt_Zone_2 INT 131 Heating Derivative Time Zone 2 + 90.0 AL1_Zone_2 INT 100 Cooling Derivative Time Zone 2 INT -10 Alarm 1 Min Temp Zone 2 + 94.0 ALHb_Zone_2 INT 20 Alarm 2 Max Temp Zone 2 + 96.0 tYP_Zone_3 INT 360 Alarm Hb Amper Zone 2 INT 2 + 100.0 HStA_Zone_3 INT 1000 Max Input Zone 3 + 102.0 Ctr_Zone_3 INT 1400 Max limit TA Zone 3 INT 14 + 106.0 HpL_Zone_3 INT 1000 Max power heating % Zone 3 INT 0 Min power heating % Zone 3 INT 300 Max Setpoint Zone 3 INT 19 Alarms enabling Zone 3 INT 0 Alarm 1 reference Zone 3 INT 0 Alarm 2 reference Zone 3 INT 3 Alarm 1 type Zone 3 INT 2 Alarm 2 type Zone 3 INT 0 Alarm HB type Zone 3 INT 30 Delay time for alarm HB Zone 3 + 86.0 Hdt_Zone_2 + 92.0 AL2_Zone_2 + 98.0 HiS_Zone_3 + 104.0 HpH_Zone_3 + 108.0 HiL_Zone_3 + 110.0 ALn_Zone_3 + 112.0 A1r_Zone_3 + 114.0 A2r_Zone_3 + 116.0 A1t_Zone_3 + 118.0 A2t_Zone_3 + 120.0 HbF_Zone_3 + 122.0 Hbt_Zone_3 + 124.0 Lbt_Zone_3 + 126.0 HPb_Zone_3 + 128.0 CPb_Zone_3 + 130.0 Hit_Zone_3 Probe/Input type Zone 3 Control Type Zone 3 INT 300 Delay time for alarm LBA Zone 3 INT 12 Heating Proportional bande Zone 3 INT 10 Cooling Proportional bande Zone 3 INT 527 Heating Integral Time Zone 3 + 134.0 Hdt_Zone_3 INT 100 Cooling Integral Time Zone 3 INT 131 Heating Derivative Time Zone 3 + 138.0 AL1_Zone_3 INT 100 Cooling Derivative Time Zone 3 + 140.0 AL2_Zone_3 INT -10 Alarm 1 Min Temp Zone 3 INT 20 Alarm 2 Max Temp Zone 3 + 144.0 tYP_Zone_4 INT 360 INT 2 INT 1000 Max Input Zone 4 INT 1400 Max limit TA Zone 4 + 132.0 Cit_Zone_3 + 136.0 Cdt_Zone_3 + 142.0 ALHb_Zone_3 + 146.0 HiS_Zone_4 + 148.0 HStA_Zone_4 + 150.0 Ctr_Zone_4 Alarm Hb Amper Zone 3 Probe/Input type Zone 4 INT 14 + 154.0 HpL_Zone_4 INT 1000 Max power heating % Zone 4 INT 0 Min power heating % Zone 4 + 158.0 ALn_Zone_4 INT 300 Max Setpoint Zone 4 INT 19 Alarms enabling Zone 4 INT 0 Alarm 1 reference Zone 4 INT 0 Alarm 2 reference Zone 4 INT 3 Alarm 1 type Zone 4 INT 2 Alarm 2 type Zone 4 INT 0 Alarm HB type Zone 4 INT 30 Delay time for alarm HB Zone 4 + 152.0 HpH_Zone_4 + 156.0 HiL_Zone_4 + 160.0 A1r_Zone_4 + 162.0 A2r_Zone_4 + 164.0 A1t_Zone_4 + 166.0 A2t_Zone_4 + 168.0 HbF_Zone_4 + 170.0 Hbt_Zone_4 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA Control Type Zone 4 37 Address Name + 172.0 Lbt_Zone_4 + 174.0 HPb_Zone_4 + 176.0 CPb_Zone_4 + 178.0 Hit_Zone_4 + 180.0 Cit_Zone_4 + 182.0 Hdt_Zone_4 + 184.0 Cdt_Zone_4 + 186.0 AL1_Zone_4 + 188.0 AL2_Zone_4 + 190.0 ALHb_Zone_4 = 192.0 Type INT Initial value Comment 300 Delay time for alarm LBA Zone 4 INT 12 Heating Proportional bande Zone 4 INT 10 Cooling Proportional bande Zone 4 INT 527 Heating Integral Time Zone 4 INT 100 Cooling Integral Time Zone 4 INT 131 Heating Derivative Time Zone 4 INT 100 Cooling Derivative Time Zone 4 INT -10 Alarm 1 Min Temp Zone 4 INT 20 Alarm 2 Max Temp Zone 4 INT 360 Alarm Hb Amper Zone 4 END_STRUCT GEFRAN S.p.A. via Sebina, 74 25050 Provaglio d’Iseo (BS) Italy Tel. 030 98881 - Fax 030 9839063 www.gefran.com 38 80419B_MSW_PROFINET per GFXtermo4-GFX4_06-2014_FRA