Sammelschienenadapter Busbar adapter Adapteur Adattatore Adaptador Achtung: Vor Installations- oder Servicearbeiten Stromversorgung unterbrechen, um Unfälle zu vermeiden. Die Geräte müssen in einem passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden. Inbetriebsetzung und Wartung nur durch Fachpersonal! Attention: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. To be commissioned and maintained only by qualified personnel! UL! Applikation 32 973 / 32 974 Attention: Avant le montage et la mise en service, couper l‘alimentation secteur afin d‘éviter tout accident. Prévoir une mise en coffret ou armoire appropriée. Protéger le produit contre les environnements agressifs. Mise en service en entretien: seulement par du personnel spécialisé! Attenzione: Per prevenire infortuni, togliere tensione prima dell‘installazione o manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti. Messa in servizio e manutenzione solo da personale specializzato! Atención: Con el objeto de evitar accidentes, hay que desconectar la alimentación eléctrica antes de realizar el montaje y la puesta en marcha. Debe instalarse en una caja o armario apropiado. Debe protegerse el producto de los ambientes agresivos. La puesta en marcha y el mantenimiento ha de hacerlo exclusivamente por personal especializado! Suitable for use on a circuit capable of delivering not more than 65kA SCCR Symetrical Ampers, 480 Volts maximum. When protected by a circuit Breaker having an interrupting rating not less than 65kA SCCR Symetrical Ampers, 480 Volts maximum. Suitable for use on a circuit capable of delivering not more than 50kA SCCR Symetrical Ampers, 600 Volts maximum. When protected by a circuit Breaker having an interrupting rating not less than 50kA SCCR Symetrical Ampers, 600 Volts maximum. C UL EEC6025-L, EEC6032-L, EEC6063-L, EEC6080-L, EEC6000-L US LISTED ® IND.CONT.EQ. 3SFY 1. Schienensystem Suitable for use on a circuit capable of delivering not more than 100kA SCCR Symetrical Ampers, 600 Volts maximum. When protected by a circuit Breaker having an interrupting rating not less than 100kA SCCR Symetrical Ampers, 600 Volts maximum. Busbar system 0021-4-01 0028-4-02 5, 12 25 , 15, , 3 20 0m , m 10 5 mm mm R= 0,5 mm 60 5 mm 60 mm Klick mm 10 mm Technische Änderungen vorbehalten. 1.1 woe0549-01 © KHW 10 mm 94 255 000-1 1.2 Stand 03.2009 2. Vorbereitung für die Montage Preparations for the assembly 0548-4-01 0012-4-01 Md ! UL 32 973 32 974 Md x M d = 0,5 – 0,8 Nm Baubreite Klemmraum in mm in mm 2 2.1 3. Montage Adapter Nr. Md Md x in Nm in lb.in. in mm 45 0,75 – 6 1 2 17 10 54 – 81 1,5 – 16 2 3 27 11 2.2 Assembly of the adapter 0043-4-00 0032-4-01 Klick 3.1 4. Demontage Adapter 3.2 Disassembly of the adapter 0044-4-00 0036-4-01 Klick 4.1 Technische Änderungen vorbehalten. woe0550-01 © KHW 4.2 94 255 000-1 Stand 03.2009 ">

Public link updated
The public link to your chat has been updated.