Unilamp ZET5 Round Adjustable - CVDA Mode d'emploi
PDF
Descarregar
Documento
INSTALLATION MANUAL PRODUCT NAME : ZET5 Round Adjustable,ZET5 Round Adjustable - CV,ZET5 Round Adjustable - CVDA : ZET6 COB Adjustable Clear,ZET6 Optic Adjustable Clear 1. 2. Constant Current 250mA (CC) Constant Current 700mA (CC) 8. 9. 68.5 /Ta 35°C 9013/9023-A-2-901-91 *** 68.5 /Ta 35°C 9013/9023-A-2-904-91 *** 68.5 /Ta 35°C 9013/9023-A/B/C-2-528-91 *** 65.5 9013/9023-A/B/C-2-529-91 *** 65.5 9013/9023-A/B/C-2-530-91 *** 65.5 9013/9023-A/B/C-7-583-91 * 64.5 /Ta 40°C ( Output from SELV system only) 9013/9023-A/B/C-7-584-91 * ( ¡ÃÐáÊ俵ͧÁÒ ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò 9013/9023-A/B/C-7-585-91 * µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑ à¾Õ§à·Ò¹Ñé¹ ) 64.5 /Ta 40°C 6. 7. 9013/9023-A-2-503-91 *** Constant Voltage LED 24V 64.5 /Ta 40°C Unit: mm. 2 1-3 4-9 Light Emitting Diodes (LED) Light Emitting Diodes (LED) 2.1 130 1 IP67 + 5. Glass Temperature At Ta 50°C *** - + 3. 4. Ordering Code Input lll - No. * û129 20° 2.2 173 173 130 20° û108 ZET5 2.3 û108 2.4 ZET6 3 Please note the ground level. ¢Í¤ÇÃÃÐÇѧ: ¼ÔÇ˹ҢͧµÑÇâ¤Á¡Ñº ¼ÔǾ×鹤ÇÃÍÂÙã¹ÃйҺà´ÕÂǡѹ 6 25 Cable size : 2X1.00 mm.2 Ø6-13mm. ¢¹Ò´ÊÒÂä¿ Last Revised On : 31/10/2024 REV.09 Ø122 170 1/7 FR-DD-29 REV.00 EFF 11/03/24 5 4 5.1 4.2 5.2 5° 20° 15° 10° 4.3 Section-View inside luminaire. ÀÒ¾µÑ´ÀÒÂã¹µÑÇâ¤Áä¿ Adjustable optic unit. ÊÒÁÒö»ÃѺµíÒá˹§ä´µÒÁ¤Ò·ÕèÃÐºØ 5.3 4.1 6 Torque/áçºÔ´ : 2.0 Nm. 7 1 6.2 7.4 3 4 2 6.1 Lock the screws following this sequence. ¤ÇâѹʡÃÙµÒÁÅíҴѺ¢Í§ËÁÒ àÅ¢·ÕèÃкØäǵÒÁÃÙ»ÀÒ¾ Torque/áçºÔ´ : 1.0 Nm. 1 3 4 Torque/áçºÔ´ : 1.0 Nm. 2 7.3 6.3 Warranty void if rem oved. ÊÔé ¹ ÊØ ´¡ÒÃÃÑ º »ÃÐ¡Ñ ¹ËÒ¡¶Ù ¡á¡ÐÍÍ¡ Lock the screws following this sequence. ¤ÇâѹʡÃÙµÒÁÅíҴѺ¢Í§ËÁÒ àÅ¢·ÕèÃкØäǵÒÁÃÙ»ÀÒ¾ Warranty void if removed. ÊÔé¹ÊØ´¡ÒÃÃѺ»ÃСѹ ËÒ¡¶Ù¡á¡ÐÍÍ¡ 7.1 8 Torque/áçºÔ´ : 1.0 Nm. Installation complete ¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó Last Revised On : 31/10/2024 REV.09 7.2 2/7 FR-DD-29 REV.00 EFF 11/03/24 9.A For Remote Driver./ÊíÒËÃѺ ÃÕâÁ· ä´ÃàÇÍà lll Use the rubber seal according to the size of the cable àÅ×Í¡ãªÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´ µÒÁ¢¹Ò´¢Í§ÊÒÂä¿ Please prepare the space for installation. ¤ÇÃàµÃÕÂÁ¾×é¹·Õèà¼×èÍÊíÒËÃѺ¡ÒõԴµÑé§äÇ´Ç Rubber seal size ÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´·Õè㪠No. Cable size : ¢¹Ò´ÊÒÂä¿ 1. Cable size dia Ø5-6 mm. ¢¹Ò´ÊÒÂä¿ with washer. áËǹÃͧ 2. Cable size dia Ø8-9 mm. ¢¹Ò´ÊÒÂä¿ with washer. áËǹÃͧ 6 dia 9 mm. 1 5 3 4 6 2 Output/ÍÍ¡ to Luminaire Input/à¢Ò 220-240V Cable size : ¢¹Ò´ÊÒÂä¿ 3. Cable size dia Ø10-11 mm. ¢¹Ò´ÊÒÂä¿ with washer. áËǹÃͧ dia 6 mm. 9 Rubber seal size ÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´·Õè㪠No. 4. Cable size dia Ø12-13 mm. ¢¹Ò´ÊÒÂä¿ with washer. áËǹÃͧ 11 dia 11 mm. 13 dia 13 mm. Lock the screws following this sequence. ¤ÇâѹʡÃÙµÒÁÅíҴѺ¢Í§ËÁÒÂàÅ¢·ÕèÃкØäÇ µÒÁÃÙ»ÀÒ¾ L Warning Please ensure that the led lamp is connected to the driver correctly. Wrong polarity connection cause a damage to the led lamp and driver. â»Ã´ÃÐÇѧ¡ÒõÍÊÒÂä¿ÊÅѺ¢ÑéÇ +ºÇ¡ -ź ¨Ò¡ä´ÃàÇÍÃÁÒà¢Ò·ÕèËÅÍ´ LED ËÒ¡µÍÊÅѺ¢ÑéÇ ¨Ð·íÒãËä´ÃàÇÍÃáÅÐËÅÍ´ LED à¡Ô´¤ÇÒÁàÊÕÂËÒ Rubber seal/ ÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´ Distance from luminaire to Driver/transformer ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà /ËÁÍá»Å§ Conductor size / ¢¹Ò´ÊÒÂä¿ Maximum number of luminaires Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Make sure that cable glands are fastened. ¢Ñ¹à¤àºÔÅá¡Åç¹´ãËá¹¹ Washer/ áËǹÃͧ Cable gland M20x1.5/ à¤àºÔÅá¡Åç¹´ N Accessory Name for Series Circuit connection / ¨íҹǹâ¤Á㹡ÒõÍẺ͹ءÃÁ 1.00 mm2 AUN-DRG-0013-00 LED Constant Current Driver 250mA 10W. In IP67 GFR Polymer Box (On-Off) 1 luminaire/â¤Á 25 m AUN-DRG-0014-00 LED Constant Current Driver 250mA 13W. In IP67 GFR Polymer Box (DIM 1-10V) 1 luminaire/â¤Á 150 m AUN-DRG-0015-00 LED Constant Current Driver 250mA 11W. In IP67 GFR Polymer Box (DALI) 1 luminaire/â¤Á 150 m AUN-DRG-0002-01 LED Constant Current Driver 700mA 1-20W. In IP67 GFR Polymer Box 1 luminaire/â¤Á 150 m AUN-DRG-0005-01 LED Constant Current Driver 700mA 20W. In IP67 GFR Polymer Box (DIM 1-10V) 1 luminaire/â¤Á 150 m AUN-DRG-0010-00 LED Constant Current Driver 700mA 38W. In IP67 GFR Polymer Box (DALI) 2 luminaires/â¤Á 150 m Luminaires 1-n 9.B For Constant Voltage LED 24Vdc / CVDA Warning : Luminaire must be operated with remote driver that is conform to SELV 1 L N AC n 2 + DC - DALI DA Control DA Distance from luminaire to Driver/transformer ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà /ËÁÍá»Å§ Luminaire Wattage Maximum number of luminaires Conductor size / ¢¹Ò´ÊÒÂä¿ for parallel connection / ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ 1.00 mm2 1.50 mm2 2.00 mm2 Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name AUN-DRG-0027-00 LED Constant Voltage Driver 24V 72W. 8.1 W 1-10 luminaires/â¤Á 25 m 40 m 50 m LED Constant Voltage Driver 24Vdc 150W. 8.1 W 1-8 luminaires/â¤Á 38 m 58 m 77 m AUN-DRG-0011-00 Last Revised On : 31/10/2024 REV.09 3/7 FR-DD-29 REV.00 EFF 11/03/24 General installation guide ( highly recommended) ¢Íá¹Ð¹íÒ㹡ÒõԴµÑé§ Pic-1 ÃÙ»-1 20-30 cm. Pic-2 ÃÙ»-2 Cable pipe Place the gravel 20-30 cm.depth underneath the casing for water drainage (Pic-1).Then do the testing by filling water into the casing and let it drain.The water should be drained out by 30 minutes. If not,the additional drainage pipe or other system must be applied (Pic-2) ¤ÇÃÇÒ§¡Í¹¡ÃǴ㵡Åͧ½§¾×é¹·ÕèÃÐÂÐÅÖ¡»ÃÐÁÒ³ 20-30 «Á. à¾×èͪÇÂÃкÒ ¹éíÒ·Õè·ÇÁ¢Ñ§µÑÇâ¤Áä¿ ÊÒÁÒö·´Êͺ¡ÒÃÃкÒ¹éíÒâ´Âà·¹éíÒãÊ¡ÅͧãËàµçÁ ¹éíҨеͧÃкÒÂÍÍ¡ËÁ´ÀÒÂã¹àÇÅÒ 30¹Ò·Õ ËÒ¡äÁ໹µÒÁ¹Ñ鹤ÇÃÁÕ¡ÒÃµÍ ·ÍÃкÒ¹éíÒà¾ÔèÁàµÔÁ Water drainage pipe ·Í¹éíÒ·Ôé§ Installation should not be done under high humidity environment i.e. rainy day or after the rain,foggy weather....ect. äÁ¤ÇõԴµÑé§â¤Áä¿ã¹ªÇ§·ÕèÁÕ¤ÇÒÁª×é¹Ê٧હ Çѹ·Õè½¹µ¡µÅÍ´ËÃ×͵ԴµÑé§ËÅѧ ½¹ËÂØ´µ¡à¾ÃÒШзíÒãˤÇÒÁª×鹶١¢Ñ§äÇã¹µÑÇâ¤Áä¿ËÅѧ¨Ò¡¹Ñ鹨Ðà¡Ô´¡Òà ¤Çºá¹¹à»¹ÅÐÍͧËÃ×ÍË´¹éíÒà¡ÒеԴºÃÔàdz㵡ÃШ¡ÀÒÂã¹µÑÇâ¤Áä¿ Do not let the exposed part of the fittings be covered by the soil,dried weed or foliage as well as corrosive or aggressive substancechemicals. ÍÂÒ»ÅÍÂãËÁÕÊÔè§Ê¡»Ã¡àª¹ àÈÉ´Ô¹ ãºäÁ ËÃ×Í Ë­Òá˧ÃÇÁ¶Ö§à¤ÁÕ·Õè໹ÊÒÃ-¡Ñ´¡Ã͹ÁÒ»¡¤ÅØÁÊÐÊÁºÃÔàdz˹Ҿ×é¹¼ÔǵÑÇâ¤Áä¿ Do not throw or drop any hard objects onto the top of fittings. ÍÂÒãËÇѵ¶Ø·Õè໹¢Í§á¢ç§ËŹ ËÃ×͵¡¡ÃÐá·¡ãʺÃÔàdz˹Ҿ×é¹¼ÔǢͧµÑÇâ¤Á The surface temperature of the fitting can be very high after continuation in service. àÁ×èÍà»´ä¿·Ôé§äÇã¹ÃÐÂÐàÇÅÒ˹Ö觨Ðà¡Ô´¤ÇÒÁÃ͹ÊÐÊÁºÃÔàdz´Ò¹º¹¢Í§µÑÇâ¤Á俤ÇÃÃÐÁÑ´ÃÐÇѧ ¡ÒÃÊÑÁ¼Ñʶ١ºÃÔàdz´Ñ§¡ÅÒÇ Proper use of this fitting must be observed. ¤ÇþԨÒóҤÇÒÁàËÁÒÐÊÁ¢Í§¾×é¹·ÕèËÃ×͵íÒá˹§·Õè¨ÐµÔ´µÑ駵ÑÇâ¤Áä¿ µÑÇÍÂÒ§ હ ÁÕ ¹éíҢѧ໹»ÃШíÒ㹺ÃÔàdz¹Ñé¹ËÃ×ÍäÁ? , Çѵ¶ØµÒ§æ હ ´Ô¹,àÈÉãºäÁãºË­ÒÁÕâÍ¡ÒÈ·Õè¨ÐÁÒ»¡¤ÅØÁÊÐÊÁº¹Ë¹Òâ¤Á໹»ÃÔÁÒ³ÁÒ¡ËÃ×ÍäÁ? áÅÐäÁ¤ÇõԴµÑé§ã¹ºÃÔàdz·ÕèÍÒ¨ÁÕâÍ¡Òȶ١ÊÑÁ¼ÑÊâ´Â¤¹ â´Â੾ÒÐà´ç¡àÅç¡ËÃ×ÍÊѵÇàÅÕé§ Walk over fittings.Max 1000 Kg pressure load. â¤Ã§ÊÃÒ§¢Í§â¤Á俪¹Ô´¹ÕéÊÒÁÒöà´Ô¹àËÂÕºº¹Ë¹Òâ¤Áä´ áÅÐÃѺáç¡´·Ñºä´ 1,000 ¡¡. Last Revised On : 31/10/2024 REV.09 4/7 FR-DD-29 REV.00 EFF 11/03/24 YES/¶Ù¡µÍ§ NO/äÁ¶Ù¡µÍ§ Remark : ËÁÒÂà赯 NO/äÁ¶Ù¡µÍ§ Warning : ¢Í¤ÇÃÃÐÇѧ 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡Òà µÔ´µÑé§äÁ¶¡Ù ÇÔ¸,Õ ãª§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. This is class 3 luminaire fixture. â¤Á俪¹Ô´¹Õé¨Ñ´ÍÂÙã¹ »ÃÐàÀ· 3 ( CLASS III ) ¤×Íãªä¿âÇÅ·µíÒè 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշÕèÁÕªé¹Ô Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕ蹪Թé ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ For Class I. Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø6-13 mm. For Class III. lll Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm.2 Ø6-13 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶¡Ù ÃѧÊÕÂÙÇÕä´ NO 0.5 m Last Revised On : 31/10/2024 REV.09 Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õ趡٠ÊͧÊÇÒ§ 5/7 FR-DD-29 REV.00 EFF 11/03/24 Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ NO Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ)ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕ觷Õè¨Ðà¡Ô´¤ÇÒÁàÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± For Class I. LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230 V For Class III. LED LED Last Revised On : 31/10/2024 REV.09 To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ 6/7 FR-DD-29 REV.00 EFF 11/03/24 Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹éÃÕ ÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫íÒé «Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁ¡Õ ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 31/10/2024 REV.09 7/7 FR-DD-29 REV.00 EFF 11/03/24 ">

Link público atualizado
O link público para o seu chat foi atualizado.