Elkay FHD7005*2EJO Manuel utilisateur
PDF
Скачать
Документ
FHD7005*2EJO, FHD7005*3EJO Space-ette With FLEXI-GUARD ® Installation/Care/Use Manual USES HFC-134A REFRIGERANT 34 (SEE FIG. 5) SEE FIG. 3 7 SEE FIG. 4 27, 28 33 (SEE PAGE 3) 43 26 30 31 & 32 13 18 19 16 17 & 20 15 29 44 14 21 22, 23, 24, 25 41 & 42 FIG. 1 PAGE 1 97596C (Rev. A - 3/01) FHD7005*2EJO, FHD7005*3EJO FINISHED FLOOR PISO ACABADO PLANCHER FINI FIG. 2 LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIAM. EXT. A 1-1/2" (38mm) FUERA DE LA LLAVA DE PASO EN LA PARED COLOCADA POR TERCEROS. EMPLACEMENT RECOMMANDÉ DALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRET FOURNI PAR D'AUTRES. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/4" DE DIÁMETRO. EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU. C = 1-1/4 TRAP NOT FURNISHED PURGADOR DE 1-1/4 NO PROPORCIONADO SIPHON 1-1/4 NON FOURNI D = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR. E = POWER CORD 4 FEET (1219mm) LONG CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO CORDON DALIMENTATION 4' (1219mm) 97596C (Rev. A - 3/01) PAGE 2 FHD7005*2EJO, FHD7005*3EJO SERVICING THE HOT CONTROL AND FUSE ASSEMBLY 1. A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat. The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4). 2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for proper temperature control. Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank. 3. The heater element jacket must be fastened VERY TIGHTLY to the tank (45+/-10 inch-lbs. of torque on the mounting screw Item 9). Failure to TIGHTEN heater element jacket may cause rapid failure of the fuse assembly. HOT TANK PARTS LIST 7 12 10 ITEM NO. PART. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 NS 22111C 22112C 22113C 30980C 31386C 31428C 50787C 70606C 70607C 70640C 70659C 70683C 70793C 22588C 3 5 6 4 9 1 2 8 13 11 Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove Items 1 & 2 and adjust screw on Item 4. Clockwise adjustment will raise stream and counterclockwise adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2" (165mm) from bubbler. DESCRIPTION Heater Clamping Bracket Heater Clamping Bracket (thrd) Retaining Bracket Heater Element & Jacket Tank & Tube Assy Hot Control Assy Washer-Spacer Drain Plug Screw 1/4-20 x 3.00" HSHC Screw #8-18 x 5/16" HHTC Belleville Washer 1/4 Union 1/4 Elbow Hot Tank Mounting Bracket 10 9 8 11 1 BASIN 2 3 12 4 NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 12) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. 5 BASIN 6 FIG. 3 FIG. 4 WIRING DIAGRAM 35 This Drawing is merely for illustrating the components of the electrical system. 36 38 37 40 39 FIG. 5 PAGE 3 97596C (Rev. A - 3/01) FHD7005*2EJO, FHD7005*3EJO PARTS LIST 115V ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22* 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 NS PART NO. 40089C 40048C 15005C 61313C 40169C 50986C 45439C 51349C 40322C 50934C 50168C 70012C 31513C 31455C 31456C 31457C 31458C 31459C 31460C 66303C 50189C 31430C 30664C 20282C 70018C 66200C 35788C 31035C 31797C 194243901550 55996C 40570C 55835C 66300C 66504C 21591C 30010C 31406C 40582C 40597C 92712C 51543C 40596C 70921C 33659000 50144C 70418C 27058C 27059C 27061C 36016C 21482C 20460C 27358C DESCRIPTION Cover Button Regulator Retaining Nut Regulator Hex Nut Regulator Holder Basin & Precooler Assy Bubbler Assy Orifice Assy Housing Assy Pedestal Bubbler Locknut Cold Control Cord - Power "JB" Cord - Power "JC" Cord - Power "JD" Cord - Power "JJ" Cord - Power "JS" Cord - Power "JM" Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compressor Serv. Pak Overload/Relay Assy Cover - Relay Electrical Shield Strainer Precooler Assy Tailpipe Helix Heat Exchanger Evaporator Hot Tank Switch Bracket Hot Tank Switch Hot Tank Assy Hot Valve Assy Gooseneck Hot Valve Kit Handle Shroud Mounting Nut Body Gasket Grommet-Compressor Washer-Compressor Cabinet-Sandalwood Cabinet-Stainless Steel Cabinet-Granite Cord - Power 230V Front Panel-Sandalwood Front Panel-Stainless Steel Front Panel-Granite *REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to ELKAY water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part. PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484 97596C (Rev. A - 3/01) PAGE 4 ">

Публичная ссылка обновлена
Публичная ссылка на ваш чат обновлена.